B Error Messages


This appendix lists the meaning of pROBE+ error messages. Some explanations describe possible causes for the error.

API Reserved entries
This API name is reserved.

Bad Command Parameter
Invalid parameter given to a command.

Break Point Already Set
The break point you are attempting to set has already been set.

Break Table Full
On a DB command, the break table for the break type is full.

Bus Error Exception
A command was entered that caused a bus error when the pROBE+ debugger attempted to reference data. Referencing nonexistent memory is the usual cause of this message.

Cannot Set Breakpoint
The pROBE+ debugger was unable to set the specified breakpoint An attempt to set a breakpoint in ROM is the usual cause of this message.

Component Not Installed
You specified an uninstalled component name to Query Services.

Console Interface Executive Reserved entries
The entry you have made is reserved for the Console Interface Executive.

Context Unavailable
Context registers of the running task are not saved. The processor registers may be used instead if the current context reflects the task running and not an Interrupt Service Routine (ISR).

Date/Time not Initialized
The date and/or time was referenced but the time has not been set since the pSOS+ kernel was initialized.

Delay Slot Break Not Allowed
The delay slot break being used is not allowed.

DISASSEMBLER Sub-Component Not Installed
You tried to use the DI command with no pROBE+ disassembler module installed.

Extra Parameter
Too many parameters have been entered for the command.

Internal Error
The pROBE+ debugger is not functioning correctly. A corrupted pROBE+ data area may cause this error.

Interrupted by Manual Break
A manual break was used to terminate the current command.

Invalid ASCII Constant
The constant you entered is an invalid ASCII character. Check an ASCII character set table and reenter a valid character.

Invalid Break Number
On a CB command, a break index must be in the range of 0 through 16.

Invalid Number
A number field contains a nonnumeric character.

Invalid Parameter
You entered an out-of-sequence parameter of a type that was unexpected (a number instead of an object, for example).

Invalid Range
The memory range entered is not valid because the ending address is less than the starting address.

Invalid Register
The pROBE+ debugger did not recognize the register name entered, or the register is invalid on the current processor type.

Invalid S-Record
When reading S-record-formatted data from a host computer, the pROBE+ debugger encountered an erroneous record. dd is a decimal number (counting from 1) that indicates the record containing the error.

Invalid Width
The data width field must be .C, .S, or .L.

Missing Parameter
Not all parameters required by the command have been entered.

Named Object not Found
The name entered does not correspond to an active object of the correct type.

No Console Input
The command or service you are running requires input from the console.

Node Number Invalid
The node number entered is invalid; verify the number and reenter.

Object Type Invalid
The object type entered is invalid; verify the object type and reenter the command.

Processor Services Reserved Entries
The Processor Services entries you have used are reserved.

pSOS Not Initialized
This command can only be entered after the pSOS+ kernel has been started.

QUERY Sub-Component Not Installed
You tried to use the QQ command with no pROBE+ QUERY module installed.

Service Interrupted by Manual Break
The service you were running was interrupted by a manual break. Check the cause of the interruption and restart the service as needed.

Service Unknown or Unavailable
The service you specified is unknown or unavailable. Verify the spelling and capitalization of the service and enter it again.

Unexpected Break
A breakpoint exception occurred with no breakpoints set by a DB command.

Unknown Command
Command not recognized and either URCOM has not been provided or URCOM rejected the command.

Unknown Option
The option you have entered is unknown. Verify the spelling and capitalization and reenter.

Unknown Service
An unrecognized or invalid service call was entered on a DB command.